CHEN Rong, REN Xiaomin, YU Ye, GUO Jin, LU Peihua, LI Li. Application of improved electrocardiograph connector in tip positioning of PICC[J]. Journal of Clinical Medicine in Practice, 2020, 24(8): 14-17. DOI: 10.7619/jcmp.202008004
Citation: CHEN Rong, REN Xiaomin, YU Ye, GUO Jin, LU Peihua, LI Li. Application of improved electrocardiograph connector in tip positioning of PICC[J]. Journal of Clinical Medicine in Practice, 2020, 24(8): 14-17. DOI: 10.7619/jcmp.202008004

Application of improved electrocardiograph connector in tip positioning of PICC

More Information
  • Received Date: February 01, 2020
  • Objective To explore the improvement method of electrocardiograph connector and its clinical application effect. Methods The improved electrocardiograph connector was designed and applied in clinic according to the problems existing in unimproved electrocardiograph connector. The wear-out rate of electrocardiograph connector, the stability of electrocardiograph waveform and cathetering in place rate of peripherally inserted central catheter(PICC)tube before and after improvement were compared. Results The wear-out rate, the stability of ECG waveform and the cathetering in place rate of PICC of the improved ECG connector were better than those of unimproved electrocardiograph connector(P<0.05 or P<0.01). Conclusion The structure design of the improved electrocardiograph connector is more reasonable, and its performance is stable. The effect of the PICC tip positioning is better, and it is durable, and the feature of the machine with multiple purpose realizes the connection with many electrocardiograph equipments.
  • 袁玲, 李蓉梅, 李善萍, 等. 两种方法经三向瓣膜式PICC引导腔内心电图的效果比较[J]. 中华护理杂志, 2015, 50(9): 1055-1059.
    赵林芳, 曹秀珠, 陈春华, 等. 心内心电图特异性P波形态变化在瓣膜式PICC头端定位中的应用研究[J]. 中华护理杂志, 2015, 50(11): 1374-1378.
    Rossetti F, Pittiruti M, Lamperti M, et al. The intracavitary ECG method for positioning the tip of central venous access devices in pediatric patients: results of an Italian multicenter study[J]. J Vasc Access, 2015, 16(2): 137-143.
    黄芬, 梅赣红, 张玉红, 等. 自制心电连接转换器在PICC尖端定位的临床研究[J]. 护士进修杂志, 2015, 30(16): 1518-1519.
    李迎. 自制心电连接器在PICC置管尖端定位的应用[J]. 中国医学创新, 2018, 15(10): 120-123.
    Infusion Nurses Society. Infusion Therapy Standards of practice[J]. J Infus Nurs, 2016, 39(1 Suppl): 38-38.
    姚辉, 宋敏, 刘玉莹. 静脉内心电图引导PICC尖端定位的临床研究[J]. 中华护理杂志, 2011, 46(8): 748-750.
    郭玲, 秦英, 王国蓉, 等. 成人中心静脉置管腔内心电图稳定性及影响因素研究[J]. 中华护理杂志, 2015, 50(6): 724-727.
    任晓敏, 张萍, 李丽, 等. 改进型心电定位系统用于PICC尖端定位的研究[J]. 护理学杂志, 2016, 31(14): 1-4.
    李丽, 任晓敏, 郭瑾, 等. 心电采集盒联合智能手机应用于PICC导管头端定位的效果评价[J]. 实用临床医药杂志, 2016, 20(20): 47-49.
    雷瑶, 章萍. PICC心电定位波形稳定性影响因素及对策研究进展[J]. 中国护理管理, 2018, 18(5): 710-715.
    王银环. 动态心电图干扰分析及防范[J]. 山西医药杂志, 2011, 40(9): 902-902.

Catalog

    Article views (377) PDF downloads (8) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return