SHI Dai, CHEN Hao, DU Jianwei, WU Yafei, LYU Fei. Application of three-line anchors combined with modified Mason-Allen technique in repair of moderate to massive rotator cuff tear[J]. Journal of Clinical Medicine in Practice, 2024, 28(5): 85-88. DOI: 10.7619/jcmp.20240052
Citation: SHI Dai, CHEN Hao, DU Jianwei, WU Yafei, LYU Fei. Application of three-line anchors combined with modified Mason-Allen technique in repair of moderate to massive rotator cuff tear[J]. Journal of Clinical Medicine in Practice, 2024, 28(5): 85-88. DOI: 10.7619/jcmp.20240052

Application of three-line anchors combined with modified Mason-Allen technique in repair of moderate to massive rotator cuff tear

More Information
  • Received Date: January 02, 2024
  • Revised Date: February 18, 2024
  • Available Online: March 21, 2024
  • Objective 

    To investigate the therapeutic effect of three-line anchors combined with modified Mason-Allen technique in repair of moderate to massive rotator cuff tear under arthroscopy.

    Methods 

    The clinical data of 48 patients (repair of moderate to massive rotator cuff tear using modified Mason-Allen technique) were analyzed retrospectively. According to the anchors used, patients were divided into control group (double-wire anchors, n=23) and observation group (three-wire anchors, n=25). Age, gender, operation time, the number of anchors used during operation and postoperative complications were recorded in the two groups. American shoulder and elbow surgeon (ASES) scores, Constant-Murley shoulder function scores and Visual Analogue Scale (VAS) scores were compared between the two groups before and after surgery (last follow-up). During follow-up, magnetic resonance imaging(MRI)was used to evaluate rotator cuff retear.

    Results 

    At the last follow-up, VAS score of the shoulder in the two groups was significantly lower than before surgery, constant-Murley shoulder function score and ASES score were significantly higher than before surgery (P < 0.05). The number of anchors used in the control group was significantly higher than that in the observation group (P < 0.05).

    Conclusion 

    The clinical effect of three-line anchor combined with the modified Mason-Allen technique in repair of moderate to massive rotator cuff tear is better, which is consistent with the traditional two-wire anchors, but the amount of anchors is less.

  • [1]
    DEORIO J K, COFIELD R H. Results of a second attempt at surgical repair of a failed initial rotator-cuff repair[J]. J Bone Joint Surg Am, 1984, 66(4): 563-567. doi: 10.2106/00004623-198466040-00011
    [2]
    张广瑞, 刘嘉鑫, 周建平, 等. 关节镜下肩袖损伤缝合技术研究进展[J]. 中国骨伤, 2021, 34(2): 160-164. https://www.cnki.com.cn/Article/CJFDTOTAL-ZGGU202102013.htm
    [3]
    YOO J C, KOH K H, PAE Y R, et al. Prospective randomized clinical trial of single versus double row suture anchor repair in medium to large rotator cuff tears (SS-07)[J]. Arthroscopy, 2009, 25(6): e4.
    [4]
    SHIN S J, KOOK S H, RAO N D, et al. Clinical outcomes of modified mason-allen single-row repair for bursal-sided partial-thickness rotator cuff tears: comparison with the double-row suture-bridge technique[J]. Am J Sports Med, 2015, 43(8): 1976-1982. doi: 10.1177/0363546515587718
    [5]
    GERBER C, SCHNEEBERGER A G, BECK M, et al. Mechanical strength of repairs of the rotator cuff[J]. J Bone Joint Surg Br, 1994, 76(3): 371-380.
    [6]
    SILEO M J, RUOTOLO C R, NELSON C O, et al. A biomechanical comparison of the modified Mason-Allen stitch and massive cuff stitch in vitro[J]. Arthroscopy, 2007, 23(3): 235-240, 240. e1-240. e2. doi: 10.1016/j.arthro.2006.11.007
    [7]
    ESQUIVEL A O, DUNCAN D D, DOBRASEVIC N, et al. Load to failure and stiffness: anchor placement and suture pattern effects on load to failure in rotator cuff repairs[J]. Orthop J Sports Med, 2015, 3(4): 2325967115579052.
    [8]
    LIEM D, DEDY N J, HAUSCHILD G, et al. In vivo blood flow after rotator cuff reconstruction in a sheep model: comparison of single versus double row[J]. Knee Surg Sports Traumatol Arthrosc, 2015, 23(2): 470-477. doi: 10.1007/s00167-013-2429-8
    [9]
    CASTAGNA A, GAROFALO R, CONTI M, et al. Arthroscopic rotator cuff repair using a triple-loaded suture anchor and a modified Mason-Allen technique (Alex stitch)[J]. Arthroscopy, 2007, 23(4): 440. e1-440. e4.
    [10]
    SCHEIBEL M T, HABERMEYER P. A modified Mason-Allen technique for rotator cuff repair using suture anchors[J]. Arthroscopy, 2003, 19(3): 330-333. doi: 10.1053/jars.2003.50079
  • Related Articles

    [1]HU Yangxi, LIU Yan, LI Mengzhu, DONG Xing, LI Ran, WANG Wenjuan, YE Jianping, LIU Hansong. Efficacy analysis of laparoscopic sleeve gastrectomy in treating patients with obese polycystic ovary syndrome[J]. Journal of Clinical Medicine in Practice, 2024, 28(7): 49-52. DOI: 10.7619/jcmp.20234176
    [2]ZHENG Jun, FEI Wenyong, ZHU Changren, HU Yangyang. Effect of whole-process optimization of day surgery in rotator cuff repair under arthroscopy[J]. Journal of Clinical Medicine in Practice, 2023, 27(12): 63-68. DOI: 10.7619/jcmp.20231405
    [3]HU Yangyang, WANG Zhanye, LU Yaojia, FEI Wenyong, YANG Yuxia, ZHANG Yucheng, GAO Rangshan. A comparative study of arthroscopic knotted and knotless single suture bridge technique in treatment of bursal-sided rotator cuff tear[J]. Journal of Clinical Medicine in Practice, 2023, 27(6): 44-50. DOI: 10.7619/jcmp.20223149
    [4]GUI Dongmei, CHEN Hao, LYU Fei, WU Deluo, SHI Dai, ZHOU Xuemei, HU Dandan, TU Jiayuan. Effect of postoperative kinesophobia on early rehabilitation of shoulder function after repair of rotator cuff tear[J]. Journal of Clinical Medicine in Practice, 2022, 26(24): 130-133. DOI: 10.7619/jcmp.20223172
    [5]CHEN Yaning, CHENG Jinglin. Influence of regional cerebral oxygenation monitoring on controlled blood pressure reduction in elderly patients with shoulder arthroscopy[J]. Journal of Clinical Medicine in Practice, 2021, 25(2): 32-35,39. DOI: 10.7619/jcmp.20200886
    [6]LI Yi, DAI Xu, YU Hui, QIN Han, PENG Xiaohong. Efficiency of general anesthesia combined with interscalene brachial plexus block in the repair of giant rotator cuff under shoulder arthroscopy[J]. Journal of Clinical Medicine in Practice, 2020, 24(4): 68-72. DOI: 10.7619/jcmp.202004017
    [7]ZHANG Hui, ZHUANG Wanqiang, LUO Yonggang, CHEN Jun, TIAN Peng, LEI Hai, TANG Xu, TANG Yi, WEI Qinghua. Influence of shoulder arthroscopy-assisted double pulley knotless suture bridge technique on shoulder function recovery and joint mobility of patients with rotator cuff tear[J]. Journal of Clinical Medicine in Practice, 2019, 23(9): 31-33, 37. DOI: 10.7619/jcmp.201909009
    [10]ZHU Jianhua, YU Hong, PU Weigang, QIAN Xiaojian, TANG Wei. Application of sleeve gastrectomy combined with biliopancreatic diversion in the treatment of morbid obesity[J]. Journal of Clinical Medicine in Practice, 2013, (19): 57-59. DOI: 10.7619/jcmp.201319019
  • Cited by

    Periodical cited type(1)

    1. 黄磊,钱胤华,钱平康,吴子英,徐锋,汪青. 腰椎骨密度与大型肩袖撕裂的相关性分析. 实用临床医药杂志. 2024(21): 111-115+126 . 本站查看

    Other cited types(0)

Catalog

    Article views (126) PDF downloads (4) Cited by(1)

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return